Contec MS400 Multi-Parameter Patient Simulator
Regular price
R 22,490.99
inc. VAT
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
Description:
- MS400 Multiparameter Simulator is a portable device, which can provide comprehensive physiological waveform to content general test and train requirement.
- It can check the monitor rapidly near the bed, also can test the quality warranty of ECG equipment, monitor and remote therapy equipment.
- At the same time, it can be used as the training of distinguishing from arrhythmia waveforms to the nurses.
Features:
- 3.5-inch colour TFT touch-screen, 320*240 pixels, and friendly operation interface.
- Display the output waveforms synchronously, which is convenient for user to compare with the test equipment.
- It integrates the functions of SD socket interface; user can output the custom waveform by this device.
- Built-in templates list to provide the waveform that is expressed by each preset sequence number, which is convenient for searching.
- Two operation interfaces: Chinese and English.
- Operate with keystroke and touch-screen expediently and rapidly.
- Built-in 3.7V/4000mAh (Rechargeable alkaline battery).
- Optical external power: AC 220V, 50Hz or AC 120V, 60Hz
ECG/Arrhythmia:
ECG:
- Conventional: All leads have the same voltage with the II-lead as the reference
- Amplitude: 0.5,1.0,1.5 and 2.0mV
- The accuracy of Amplitude: ±2%
- ECG Rate: 15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340 and 350 BPM
- ECG artifacts: 50 or 60 Hz, muscle, baseline drift and breathing
- The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV
- The default: 80 BPM,1mV
Arrhythmia:
- Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial
- Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
- Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular
- Contraction (PVC) 6/min,
- PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5
- PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
- Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left
- Ventricular Focus
- PVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early
- Right
- Ventricular Focus PVC1, R on T Left Ventricular Focus, R on T Right
- Ventricular Focus, Multifocal PVC
- Conduction Defects: First Degree Heart Block, Second Degree Heart Block,
- Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch
- Block
ECG Performance Testing:
- ECG amplitude: 0.5,1.0,1.5 and 2.0mV
- The accuracy of Amplitude: ±2%
- Pulse: 30 and 60 BPM, the width of pulse wave is 60 ms
- Square: 0.125 and 2.0 Hz
- Triangle: 2.0 and 2.5 Hz
- Sine: .0.5, 5, 10, 40, 50, 60 and 100 Hz
- ECG Rate:15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240,
- 260, 280, 300, 320, 340 and 350 BPM
- The accuracy of ECG Rate: ±1%
Respiration:
- Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIIN
- Respiration Impedance: 0.2, 0.5, 1.0 and 3.0 B
- Baseline Impedance:500,1000,1500 and 2000
- Apnea: 12 s, 22 s, 32 s
- ECG simulator with adjustable heart rate/12-lead output
- 33 kinds of Arrhythmia waveforms
- Pacemaker
- Two IBP channels
- Variety of respiratory impedance,apnea pauses (0 BrPM) of 12, 22 and 32 seconds.
- Standard ECG calibration
- Export square,triangle and sine with adjustable frequency
IBP:
- The default: 00/00mmHg
- Dynamic IBP
Channel 1: Artery 120/80mmHg
- Radial 120/80mmHg
- Left Ventricle 120/00mmHg
- Right Ventricle 25/00mmHg
Channel 2: Artery 120/80mmHg
- Radial 120/80mmHg
- Left Ventricle 120/00mmHg
- Right Atrium 15/10mmHg
- Right Ventricle 25/00mmHg
- Pulmonary Artery 25/10mmHg
- Left Atrium 14/4mmHg
Static-Pressure Levels:
- Channel 1: 0, 80, 160, 240, 320 and 400mmHg
- Channel 2: 0, 50, 100, 150, 200 and 250mmHg
Lead time:
Our lead times are 5-7 working days excluding weekends, public holiday’s & shipping time with our courier.
Lead times on out of stock or special-order items 6-8 weeks / 8-10 weeks
PLEASE NOTE DUE TO UNFORSEEN ROAD OR AIR FREIGHT DELAYS PARECLES CAN BE DELAYED BY A FEW DAYS.
*Please note pictures are mainly for illustration purposes, actual product and size may vary slightly*