NEO-I Infant Resuscitator
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The design is in accordance with ILCOR and AHA’s AAP’ (NRP) lastest resuscitation guidelines;
Provide effective and safe airway management during resuscitation;
Offer a safety, stable and controllable target Peak Inspirato-ry Pressure (PIP) and delivering
consistent Positive end-expiratory Pressure (PEEP) to help establish Functional Residual Capacity (FRC) and improve lung volume;
Manually operated, pneumatic driven for the infant <10kg weight, especially for premature;
Applicable for delivery room, transport NICU and other sections
Environmental Requirement
- Operating range: -18℃~50℃ Relative Humidity:≤93%
- Atmospheric pressure: 700~1060hPa
Specification
- Oxygen concentration level: 21%-100% (According to the oxygen concentration of gas supply )
- Diaphragm manometer range: -10~80cmH2O
- Accuracy: ±2% of FSD
- Input gas flow range: 5-15L/min (require the gas supply can be
set up at that flow range)
- Maximum pressure (Pmax) setting range: 1-60cmH2O (factory setting of pressure relief valve is 40cmH2O)
- Peak Inspiratory Pressure (PIP) setting range: 5L/min: 1-57cmH2O(mbar)
8L/min: 2-58cmH2O(mbar) 10L/min: 3-59cmH2O(mbar) 15L/min: 5-60cmH2O(mbar)
- The factory setting of pressure relief valve: 20cmH2O,
can be adjustable
- Positive End Expiratory Pressure (PEEP) setting range: 5L/min: 0-8cmH2O(mbar)
8L/min: 0.2-17cmH2O(mbar) 10L/min: 0.5-23cmH2O(mbar) 15L/min: 1-28cmH2O(mbar)
- Applicable time (400L, 50% air/oxygen mixture): 5L/min: 75min
10L/min: 38min 15L/min: 26min
- Dead space of resuscitator and other accessories: ≤6ml Total mass (including accessories): ≤2kg
Accessories
-
Single Use Infant Resuscitation T-Piece Circuits
T-piece Circuits include a valve that can be controlled to achieve desired PEEP level; Single use;
Through port to deliver surfactant, and the surfactant will be absorbed. Gas Supply -
Pipe
The Gas Supply Pipe provides a unique connector to the NEO-I T-piece Infant Resuscitator. -
Silicone mask
Different size can be offered, the device is designed to guarantee comfort level of an infant's face with a structural seal to reach the purpose of resuscitation.
Lead time:
Our lead times are 5-7 working days excluding weekends, public holiday’s & shipping time with our courier.
Lead times on out of stock or special-order items 6-8 weeks / 8-10 weeks
PLEASE NOTE DUE TO UNFORSEEN ROAD OR AIR FREIGHT DELAYS PARCELS CAN BE DELAYED BY A FEW DAYS.
*Please note pictures are mainly for illustration purposes, actual product and size may vary slightly*
